Item  | Specifications  | 
Individualized function  | Non-stop instantaneous power failure  | The instantaneous power failure through the load feedback energy compensation voltage reduced,Maintain the inverter in a short period of time to continue running  | 
V/F individual control  | Individually adjustable voltage and frequency preset  | 
Motor switch  | Two groups of motor parameters,Two motor switching control can be achieved  | 
Support multithreading bus  | Support for multiple field bus:Modbus,Profibus-DP,CANopen  | 
Fan control  | To control fan operation,Increase the life of fan  | 
Run  | Running command channel  | Three types of channels: operation panel reference, control terminal reference and serial communication port reference;These channels can be switched in various modes  | 
Frequency source  | There are nine types of frequency sources, such as digital reference, analog voltage reference, analog current reference, pulse reference, PLC,MS speed, PID, and serial port reference, potentiometer reference  | 
auxiliary frequency source  | There are nine types of auxiliary frequency sources,Flexible realization of auxiliary frequency tuning and frequency synthesis  | 
Input terminal  | Standard: There are eight digital input terminals, one of which can be used as high-speed pulse input;There are two analog input terminals, with optional 0 ~ 10 V input voltage or 0/4 ~ 20 mA current input;  | 
Output terminal  | Standard: Two analog output terminals,with optional 0 ~ 10 V input voltage or 0/4 ~ 20 mA current output;Two digital output terminals,one of which support 0 ~ 50 KHz square wave signal high-speed pulse output;Two relay output terminal  | 
Display and Keyboard Operation  | LED display  | Display parameter  | 
Parameter copy  | Can upload or download function code information of inverter to realize fast parameter copy.  | 
Key lock and selection function  | Achieve some or all of the keys locked, scope definition part of the keys to prevent misuse  | 
Fault alarm  | Over-voltage, under-voltage, over-current, short circuit, open phase, overload,overheat, over-voltage speed lost, current limit ,etc.  | 
Environment  | Using place  | Indoor, and be free from direct sunlight, dust, corrosive gas,combustible gas, oil smoke, vapor, drip or salt.  | 
Altitude  | 1000m, derated when above 1000m  | 
Ambient temperature  | -10 ℃ Celsius to +40 ℃ Celsius (Derated when used in the ambient temperature of 40 ℃ Celsius to 50 ℃ Celsius)  | 
Humidity    | Less than 95%RH, without condensing  | 
Vibration  | Less than 5.9m/s2(0.6g)  | 
Storage temperature  | -20 Celsius to +60 Celsius  |