Item | Specifications |
Individualized function | Non-stop instantaneous power failure | The instantaneous power failure through the load feedback energy compensation voltage reduced,Maintain the inverter in a short period of time to continue running |
V/F individual control | Individually adjustable voltage and frequency preset |
Motor switch | Two groups of motor parameters,Two motor switching control can be achieved |
Support multithreading bus | Support for multiple field bus:Modbus,Profibus-DP,CANopen |
Fan control | To control fan operation,Increase the life of fan |
Run | Running command channel | Three types of channels: operation panel reference, control terminal reference and serial communication port reference;These channels can be switched in various modes |
Frequency source | There are nine types of frequency sources, such as digital reference, analog voltage reference, analog current reference, pulse reference, PLC,MS speed, PID, and serial port reference, potentiometer reference |
auxiliary frequency source | There are nine types of auxiliary frequency sources,Flexible realization of auxiliary frequency tuning and frequency synthesis |
Input terminal | Standard: There are eight digital input terminals, one of which can be used as high-speed pulse input;There are two analog input terminals, with optional 0 ~ 10 V input voltage or 0/4 ~ 20 mA current input; |
Output terminal | Standard: Two analog output terminals,with optional 0 ~ 10 V input voltage or 0/4 ~ 20 mA current output;Two digital output terminals,one of which support 0 ~ 50 KHz square wave signal high-speed pulse output;Two relay output terminal |
Display and Keyboard Operation | LED display | Display parameter |
Parameter copy | Can upload or download function code information of inverter to realize fast parameter copy. |
Key lock and selection function | Achieve some or all of the keys locked, scope definition part of the keys to prevent misuse |
Fault alarm | Over-voltage, under-voltage, over-current, short circuit, open phase, overload,overheat, over-voltage speed lost, current limit ,etc. |
Environment | Using place | Indoor, and be free from direct sunlight, dust, corrosive gas,combustible gas, oil smoke, vapor, drip or salt. |
Altitude | 1000m, derated when above 1000m |
Ambient temperature | -10 ℃ Celsius to +40 ℃ Celsius (Derated when used in the ambient temperature of 40 ℃ Celsius to 50 ℃ Celsius) |
Humidity | Less than 95%RH, without condensing |
Vibration | Less than 5.9m/s2(0.6g) |